Summary for Test 2023-10-29-2-12

Test performed: ASTM D4791-10

Project Information

Project IdentifiersProject ID: 993908
DEA: 11427104
EFIS: 1116000154
DIST-CO-RTE-PM11-SD-8-3.0/8.3
Award Date04/12/2023
Closeout Date09/26/2024
Work DescriptionMODIFY SIGNAL & LIGHTING SYSTEMS & REPLACE MINOR CONCRETE CURB RAMP.
Location DescriptionSAN DIEGO COUNTY IN SAN DIEGO AT VARIOUS LOCATIONS FROM MISSION CENTER ROAD OVERCROSSING TO COLLEGE AVENUE OVERCROSSING
QA Service Level1 (Verified on 11/01/2022)

Sample Information

Sample Taken Date10/29/2023 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing10/30/2023 Sample typeQuality Assurance
A brief description of the sample3/4" HMA The quantity of what the sample constitutes12 boxes 3 bags
From where was the sample collectedSource First name of sampler or witnessed byJesse
Last name of sampler or witnessed byFuentes Title of sampler
Telephone number of sampler Laboratory sample identification10001-PSU
Linked DIME Sample ID2023-10-29-1 The fabricator/manufacturer/facility nameVulcan Otay
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-37-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-10-29-2
DIME Test ID: 2023-10-29-2-12
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2023-11-14

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Number
Dimensional ratio used: 5:1
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 11/03/2023
Percentage on the 6 inch sieve: 0 %
Percentage on the 5 inch sieve: 0 %
Percentage on the 4 ½ inch sieve: 0 %
Percentage on the 4 inch sieve: 0 %
Percentage on the 3 ½ inch sieve: 0 %
Percentage on the 3 inch sieve: 0 %
Percentage on the 2 ½ inch sieve: 0 %
Percentage on the 2 inch sieve: 0 %
Percentage on the 1 ½ inch sieve: 0 %
Percentage on the 1 inch sieve: 0 %
Percentage on the ¾ inch sieve: 0 %
Percentage on the ½ inch sieve: 0 %
Percentage on the ⅜ inch sieve: 0 %
Percentage on the ¼ inch sieve: 0 %
Percentage on the No. 4 sieve: 0 %
Number of 6 inch that were flat and elongated: 0 particles
Number of 6 inch that were not flat and elongated: 0 particles
Number of 5 inch that were flat and elongated: 0 particles
Number of 5 inch that were not flat and elongated: 0 particles
Number of 4 ½ inch that were flat and elongated: 0 particles
Number of 4 ½ inch that were not flat and elongated: 0 particles
Number of 4 inch that were flat and elongated: 0 particles
Number of 4 inch that were not flat and elongated: 0 particles
Number of 3 ½ inch that were flat and elongated: 0 particles
Number of 3 ½ inch that were not flat and elongated: 0 particles
Number of 3 inch that were flat and elongated: 0 particles
Number of 3 inch that were not flat and elongated: 0 particles
Number of 2 ½ inch that were flat and elongated: 0 particles
Number of 2 ½ inch that were not flat and elongated: 0 particles
Number of 2 inch that were flat and elongated: 0 particles
Number of 2 inch that were not flat and elongated: 0 particles
Number of 1 ½ inch that were flat and elongated: 0 particles
Number of 1 ½ inch that were not flat and elongated: 0 particles
Number of 1 inch that were flat and elongated: 0 particles
Number of 1 inch that were not flat and elongated: 0 particles
Number of ¾ inch that were flat and elongated: 0 particles
Number of ¾ inch that were not flat and elongated: 100 particles
Number of ½ inch that were flat and elongated: 1 particles
Number of ½ inch that were not flat and elongated: 99 particles
Number of ⅜ inch that were flat and elongated: 2 particles
Number of ⅜ inch that were not flat and elongated: 98 particles
Number of ¼ inch that were flat and elongated: 0 particles
Number of ¼ inch that were not flat and elongated: 0 particles
Number of No. 4 that were flat and elongated: 2 particles
Number of No. 4 that were not flat and elongated: 98 particles
Percentage (by number) of 6 inch particles that were flat and elongated: 0 %
Percentage (by number) of 6 inch particles that were not flat and elongated: 0 %
Percentage (by number) of 5 inch particles that were flat and elongated: 0 %
Percentage (by number) of 5 inch particles that were not flat and elongated: 0 %
Percentage (by number) of 4 ½ inch particles that were flat and elongated: 0 %
Percentage (by number) of 4 ½ inch particles that were not flat and elongated: 0 %
Percentage (by number) of 4 inch particles that were flat and elongated: 0 %
Percentage (by number) of 4 inch particles that were not flat and elongated: 0 %
Percentage (by number) of 3 ½ inch particles that were flat and elongated: 0 %
Percentage (by number) of 3 ½ inch particles that were not flat and elongated: 0 %
Percentage (by number) of 3 inch particles that were flat and elongated: 0 %
Percentage (by number) of 3 inch particles that were not flat and elongated: 0 %
Percentage (by number) of 2 ½ inch particles that were flat and elongated: 0 %
Percentage (by number) of 2 ½ inch particles that were not flat and elongated: 0 %
Percentage (by number) of 2 inch particles that were flat and elongated: 0 %
Percentage (by number) of 2 inch particles that were not flat and elongated: 0 %
Percentage (by number) of 1 ½ inch particles that were flat and elongated: 0 %
Percentage (by number) of 1 ½ inch particles that were not flat and elongated: 0 %
Percentage (by number) of 1 inch particles that were flat and elongated: 0 %
Percentage (by number) of 1 inch particles that were not flat and elongated: 0 %
Percentage (by number) of ¾ inch particles that were flat and elongated: 0 %
Percentage (by number) of ¾ inch particles that were not flat and elongated: 100 %
Percentage (by number) of ½ inch particles that were flat and elongated: 1 %
Percentage (by number) of ½ inch particles that were not flat and elongated: 99 %
Percentage (by number) of ⅜ inch particles that were flat and elongated: 2 %
Percentage (by number) of ⅜ inch particles that were not flat and elongated: 98 %
Percentage (by number) of ¼ inch particles that were flat and elongated: 0 %
Percentage (by number) of ¼ inch particles that were not flat and elongated: 0 %
Percentage (by number) of No. 4 particles that were flat and elongated: 2 %
Percentage (by number) of No. 4 particles that were not flat and elongated: 98 %
Weighted percentage of particles (by number) that were flat and elongated: 0 %
Weighted percentage of particles (by number) that were not flat and elongated: 0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/14/2023 ✔