Summary for Test 2023-08-30-52-5
Test performed: AASHTO T59-22Project Information
| Project Identifiers | Project ID: 994724 DEA: 010M0804 EFIS: 0122000084 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-255-0.5/8.6 |
| Award Date | 06/09/2023 |
| Closeout Date | 01/22/2024 |
| Work Description | MICROSURFACING, REPLACE AC SURFACING, AND MODIFY SIGNAL SYSTEMS. |
| Location Description | HUMBOLDT COUNTY IN EUREKA FROM 0.3 MILE NORTH OF EUREKA CHANNEL BRIDGE TO G STREET IN ARCATA |
| QA Service Level | 1 (Verified on 04/25/2023) |
Sample Information
| Sample Taken Date | 08/30/2023 | Sample Unique Key | 52 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/07/2023 |
| Sample type | Quality Assurance | A brief description of the sample | MSE |
| The quantity of what the sample constitutes | two emulsion samples | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Molly | Last name of sampler or witnessed by | Gibney |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | VSS Emultech West Sac | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphaltic Emulsion | Emulsion Grade | MSE |
|---|---|---|---|
| Lot Number | Not set | Sub Lot | Not set |
| Dilution Percentage Rate | Not set |
Test Details
DIME Sample ID: 2023-08-30-52
DIME Test ID: 2023-08-30-52-5
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Viscosity (Saybolt Furol) (Sec. 9))
Test Release Date: 2023-11-02
Test Results
Is Correction factor required?: Yes
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 11/01/2023
What temperature wil you be testing Saybolt Furol Viscosity?: 25 C
Certified Saybolt viscosity of the standard (Certified V): 149.0 sec
Efflux time for determination of the correction factor (ETCF1): 151.2 sec
Efflux time (t2) for determination of the correction factor (ETCF2): 151.6 sec
Correction Factor (F): 1.0 sec
Efflux time (ET) for test sample: 23.0 sec
Corrected efflux time as the Saybolt Furol viscosity (Corrected V): 23 sec
Test efflux temperature: 25 F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/2/2023 ✔