Summary for Test 2017-03-23-5-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 210097 DEA: 100L9704 EFIS: 1012000053 |
---|---|
DIST-CO-RTE-PM | 10-TUO-120-R19.5/R20.0 |
Award Date | 02/22/2016 |
Closeout Date | 10/09/2018 |
Work Description | REPLACE DECK AND RETROFIT BRIDGE. |
Location Description | IN TUOLUMNE COUNTY ON STATE ROUTE 120 FROM 7.6 MILES EAST OF YOSEMITEJUNCTION TO 4.8 MILES WEST OF THE TOWN OF MOCCASIN AT TUOLUMNE RIVER/DON PEDRO RESERVOIR (JAMES E. |
QA Service Level | 1 (Verified on 12/19/2014) |
Sample Information
Sample Taken Date | 03/23/2017 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/27/2017 |
Sample type | Quality Assurance | A brief description of the sample | A325 HDG |
The quantity of what the sample constitutes | 99 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Scott | Last name of sampler or witnessed by | Leavitt |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Universal Industrial Sales | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S2808217 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 15-40-006 15-01-005 | |
Washer Mfg. Lot Number(s) | D1782 D2656 | Bolt Specification | A325 |
Bolt Length(s) | 5.5" 4.5" 4" | Nut Specification | A563-DH |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 0.75" 0.5" | Bolt Mfg. Lot Number | BG0229 BG0609 BG0590 G8245 G8533 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-03-23-5
DIME Test ID: 2017-03-23-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2017-04-11
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 03/30/2017
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1A | S28-082-17 | 3/4\" | 47823 | 212.7 | 10 | A325 | Brian |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 4/4/2017 ✔