Summary for Test 2023-09-21-102-1
Test performed: AASHTO T210-15Project Information
Project Identifiers | Project ID: 215425 DEA: 06360244 EFIS: 0613000005 |
---|---|
DIST-CO-RTE-PM | 06-TUL-99-30.6/35.2 |
Award Date | 04/23/2021 |
Closeout Date | Not set |
Work Description | Widen Freeway & Bridge Construction (Concrete Bridge) |
Location Description | Not set |
QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
Sample Taken Date | 09/21/2023 | Sample Unique Key | 102 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/21/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA -A RAP-15 |
The quantity of what the sample constitutes | 988 Ton | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Jason | Last name of sampler or witnessed by | Ruiz |
Title of sampler | Consultant Tester | Telephone number of sampler | 5592890420 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Porterville Rock PAI | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | 06-Tul 99 J St Bridge |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 0613000005 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Conveyer Belt | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | 4 | |
Sublot number | 1 | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-09-21-102
DIME Test ID: 2023-09-21-102-1
Testing Lab: CT D06 - Visalia Field Laboratory
Test Method: AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)
Test Release Date: 2023-10-30
Test Results
Which test procedure(s) is/are used?: Procedure A and Procedure B
Input Type: Calculated
Tester's full name: Jason Ruiz
Date of test: 09/21/2023
Was strict temperature control maintained?: No
What type of water was used?: Tap
Durability Index (coarse): 87
Durability Index (fine): 60
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
06-360244_37043_230921_L4SL1_SA_T027 | 118.29 KB | 10/30/2023 | 2023-09-21-102-1 | Info |
Test was verified on 10/30/2023 ✔