Summary for Test 2023-10-20-34-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 215697
DEA: 07318204
EFIS: 0715000286
DIST-CO-RTE-PM07-LA-Route 1-4.0/4.2
Award Date09/15/2021
Closeout Date03/02/2026
Work DescriptionCM/GC Project - Work consists of constructing secant wall and slope restoration
Location Descriptionnear Point Mugu State Park 0.4 mile South of Sycamore Canyon Road.
QA Service Level1 (Verified on 08/26/2021)

Sample Information

Sample Taken Date10/20/2023 Sample Unique Key34
Date that the sample was received by the laboratory/organization performing the testing10/24/2023 Sample typeDepartment Acceptance
A brief description of the sample4X8 PCC cylinders The quantity of what the sample constitutes130 CY
From where was the sample collectedJob Site First name of sampler or witnessed byJessica
Last name of sampler or witnessed byCisneros Title of samplerAssistant Structure Representative
Telephone number of sampler Laboratory sample identification23-492
Linked DIME Sample ID The fabricator/manufacturer/facility nameAssociate Ready mixed Concrete
Transportation Laboratory (TL) Number102023 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number557237SPC
The truck number from where the sample was collected4 The batch plant ticket number from where the sample was collected7092075
Concrete batch plantAssociated Ready Mix Concrete The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-10-20-34
DIME Test ID: 2023-10-20-34-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-10-30

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 10/27/2023
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.02 in
Average diameter of cylinder 3: 4.03 in
Maximum load on cylinder 1: 50672 lb
Maximum load on cylinder 2: 51426 lb
Maximum load on cylinder 3: 50975 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.69 in^2
Cross sectional area of cylinder 3: 12.76 in^2
Compressive strength of cylinder 1: 4012.0 psi
Compressive strength of cylinder 2: 4052.5 psi
Compressive strength of cylinder 3: 3994.9 psi
Compressive strength (to nearest 10 psi): 4020 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/30/2023 ✔