Summary for Test 2017-03-27-2-1

Test performed: CONCLP 3-16

Project Information

Project IdentifiersProject ID: 211504
DEA: 060N9904
EFIS: 0612000114
DIST-CO-RTE-PM06-FRE,MAD-41U-33.1/33.4,0.0/0.3
Award Date10/13/2016
Closeout Date10/02/2019
Work DescriptionBRIDGE SCOUR MITIGATION, SEISMIC RETROFIT AND UPGRADE RAIL.
Location DescriptionFRESNO AND MADERA COUNTIES NEAR FRESNO FROM 0.1 MILE NORTH OF PERRIN ROAD UNDERCROSSING TO 0.1 MILE SOUTH OF AVENUE 9 UNDERCROSSING
QA Service Level1 (Verified on 10/05/2016)

Sample Information

Sample Taken Date03/27/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/27/2017
Sample typeQuality Control A brief description of the samplepolyester resin
The quantity of what the sample constitutes80 drums From where was the sample collectedSource
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byNunes
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namekwik Bond, Benecia Transportation Laboratory (TL) Numberc594923
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1039800
Batch number1039800 Mix number3232

Test Details

DIME Sample ID: 2017-03-27-2
DIME Test ID: 2017-03-27-2-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-05-25

Test Results


Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 03/30/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 104 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 61 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 2733 psi
Styrene ASTM D 2369 40% to 50 %: 38.3 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 606 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.14 grams
General comments (publicly viewable) (Max 1000 characters): accepted on QC results

Test was verified on 5/25/2017