Summary for Test 2023-10-24-4-4

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 994239
DEA: 010H0214
EFIS: 0118000107
DIST-CO-RTE-PM01-HUM-169-19.0/33.0
Award Date12/07/2022
Closeout Date08/21/2025
Work DescriptionCappell Walls
Location DescriptionHUMBOLDT COUNTY NEAR PECWAN FROM 3.4 MILES WEST OF CAPPELL CREEK BRIDGE TO 0.4 MILE EAST OF WEITCHPEC SCHOOL ROAD (Description of Work: Construct Soldier Pile Wall, Install Drainage, Place HMA (Type A))
QA Service Level1 (Verified on 09/22/2022)

Sample Information

Sample Taken Date10/24/2023 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing10/24/2023 Sample typeQuality Control
A brief description of the sampleConcrete Test Samples The quantity of what the sample constitutes9- 4X8 Cylinders
From where was the sample collectedFabricator First name of sampler or witnessed byDonald
Last name of sampler or witnessed byJuneman Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namePrecast Unlimited
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberPC65A0E1
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected34293
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBack of Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-10-24-4
DIME Test ID: 2023-10-24-4-4
Testing Lab: Precast Unlimited Inc.
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-12-08

Test Results


Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Donald Juneman
Date of test: 10/25/2023
Capped in accordance with?: no data
Apparent mass of submerged cylinder 1: 8.5 lb
Average diameter of cylinder 1: 4.00 in
Maximum load on cylinder 1: 29110 lb
Type of fracture pattern of cylinder 1: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 1 days
Age of specimen in hours: 0 hours
Compressive strength of cylinder (to nearest 10 psi): 2310 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/8/2023 ✔