Summary for Test 2023-10-23-2-6

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 994751
DEA: 010C5004
EFIS: 0112000292
DIST-CO-RTE-PM01-HUM-36-11.3/34.6
Award Date03/02/2023
Closeout DateNot set
Work DescriptionProject Name: Bridge Rail Replacement - 3 Bridges
Location DescriptionHely Creek, Little Larabee Creek and Butte Creek Bridge.
QA Service Level1 (Verified on 04/27/2023)

Sample Information

Sample Taken Date10/23/2023 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing10/25/2023
Sample typeQuality Assurance A brief description of the sample#5 2'-2" welded hoop
The quantity of what the sample constitutes692 From where was the sample collectedFabricator
First name of sampler or witnessed byAdrian Last name of sampler or witnessed bySanchez
Title of sampler Telephone number of sampler2137133499
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL159-258-23 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)245923
Hoop Manufacturer Lot Number(s)1-5 Material Standard CodeASTM A706
Material Grade60 Rebar Size#5
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade Steel
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2023-10-23-2
DIME Test ID: 2023-10-23-2-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2023-10-26

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: rmacias
Date of test: 10/26/2023
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1355/16mm0.3127082.1487362Ok Neckingrmacias

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 10/26/2023