Summary for Test 2023-10-17-1-2

Test performed: ASTM A970-18

Project Information

Project IdentifiersProject ID: 994751
DEA: 010C5004
EFIS: 0112000292
DIST-CO-RTE-PM01-HUM-36-11.3/34.6
Award Date03/02/2023
Closeout DateNot set
Work DescriptionProject Name: Bridge Rail Replacement - 3 Bridges
Location DescriptionHely Creek, Little Larabee Creek and Butte Creek Bridge.
QA Service Level1 (Verified on 04/27/2023)

Sample Information

Sample Taken Date10/17/2023 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing10/25/2023
Sample typeQuality Assurance A brief description of the sample#11 HRC 555
The quantity of what the sample constitutes1 Lot From where was the sample collectedManufacturer
First name of sampler or witnessed byRyan Last name of sampler or witnessed byParr
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePacific Steel Group Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB373-207-23 Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)3500030480 Head Manufacturer Lot Number(s)Lot 1
Rebar Size#11 Headed Bar Model NameHRC 555
Size of HeadReduced Size - 4x Head Connection Type
Head ShapeCircular Rebar ManufacturerNucor
Head ManufacturerPacific Steel Group Head FabricatorPacific Steel Group
Material Standard CodeASTM A706 Headed Bar Unique ID4FG-17-01

Test Details

DIME Sample ID: 2023-10-17-1
DIME Test ID: 2023-10-17-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2023-10-26

Test Results


Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: rmacias
Date of test: 10/26/2023
UTM: 400kip
Temperature: 72 f
NumLot #Area (sqin)Peak Load (lbf)Tensile Strength (psi)CommentsTested By
111.5614528993134Ok Neckingrmacias

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 10/26/2023