Summary for Test 2017-03-23-4-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211555 DEA: 044G5524 EFIS: 0415000087 |
---|---|
DIST-CO-RTE-PM | 04-SOL-29-0.8/3.0 |
Award Date | 09/19/2016 |
Closeout Date | 08/07/2018 |
Work Description | CROSSWALK ENHANCEMENTS |
Location Description | SOLANO COUNTY IN VALLEJO AT VARIOUS LOCATIONS BETWEEN CHERRY STREET AND ILLINOIS STREET |
QA Service Level | 1 (Verified on 10/27/2016) |
Sample Information
Sample Taken Date | 03/23/2017 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/27/2017 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Harris Rebar | Transportation Laboratory (TL) Number | C741363 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B1014417 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 582548 |
Hoop Manufacturer Lot Number(s) | H04 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 5 |
Diameter of Hoop | 2'-8" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Evraz |
Welding Company | Harris Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-03-23-4
DIME Test ID: 2017-03-23-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-04-04
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Arnold
Date of test: 03/27/2017
UTM: 400KIP
Temperature: 70 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2 | H04 | #5/16mm | 0.31 | 27110 | 87450 | Bar Broke | Arnold |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 3/28/2017 ✔