Summary for Test 2017-03-13-2-58
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 03/13/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/21/2017 |
Sample type | Quality Assurance | A brief description of the sample | F1554 Grade 55 HDG Anchor Bolts |
The quantity of what the sample constitutes | 107 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Reyes |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | A M Nut Bolt | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B30105117 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | PL15205107 3065464 58027948-03 3065470 58027475-06 3065469 | Nut Mfg. Lot Number(s) | DDSR 358843B W1781 382770A W1644 W2032 381629A |
Washer Mfg. Lot Number(s) | 32545 297736 299999 299482 299537 299482 | Bolt Specification | F1554-55 HDG |
Bolt Length(s) | 42" 30" 51" 36" 42" 42" 36" | Nut Specification | A563 DH A194 2H HDG |
Washer Specification | F436 HDG | Finish | HDG |
Diameter/Size | 1.75" 0.75" 2" 1" 2" 2.25" 1" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-03-13-2
DIME Test ID: 2017-03-13-2-58
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-04-03
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Arnold
Date of test: 03/24/2017
UTM: 400KIP
Temperature: 71 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 2A | 358843B | ?\" | 50885 | 226.35 | Nut Proof Load | Arnold |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 3/27/2017 ✔