Summary for Test 2023-09-26-74-6

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 995107
DEA: 081P3104
EFIS: 0823000157
DIST-CO-RTE-PM08-RIV-60-21.369/21.369
Award Date06/26/2023
Closeout Date07/31/2024
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 08/28/2023)

Sample Information

Sample Taken Date09/26/2023 Sample Unique Key74
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/25/2023
Sample typeQuality Control A brief description of the sampleT-II/V Cement & Flyash Type F
The quantity of what the sample constitutes13.8 From where was the sample collectedJob Site
First name of sampler or witnessed byBenjamin Last name of sampler or witnessed byAragon
Title of samplerQC Inspector Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCon-Fab California, LLC - Shafter Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberS9.8-25FA
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected3785
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedSampled from wheelbarrow collected from chute of ready mix truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-09-26-74
DIME Test ID: 2023-09-26-74-6
Testing Lab: Con-Fab California, LLC
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-06-11

Test Results


Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jesus Rodriguez
Date of test: 10/24/2023
Capped in accordance with?: no data
Apparent mass of submerged cylinder 1: 1 lb
Average diameter of cylinder 1: 4.00 in
Maximum load on cylinder 1: 133850 lb
Type of fracture pattern of cylinder 1: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Compressive strength of cylinder (to nearest 10 psi): 10650 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/11/2024