Summary for Test 2023-10-11-18-9
Test performed: ASTM D7741-11ε1Project Information
| Project Identifiers | Project ID: 995087 DEA: 051P5904 EFIS: 0522000086 |
|---|---|
| DIST-CO-RTE-PM | 05-SCR-1-0.0/5.0 |
| Award Date | 03/22/2023 |
| Closeout Date | 08/13/2024 |
| Work Description | Cold plane, RHMA-G |
| Location Description | Watsonville area, County line to Scenic pullout |
| QA Service Level | 1 (Verified on 08/21/2023) |
Sample Information
| Sample Taken Date | 10/11/2023 | Sample Unique Key | 18 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 10/11/2023 |
| Sample type | Quality Assurance | A brief description of the sample | 64-16 ARB |
| The quantity of what the sample constitutes | 2 Cans | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Wesley | Last name of sampler or witnessed by | Rider |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | National Blending Company | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | San Joaquin Refining Co Inc |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number | 23_1354 |
Test Details
DIME Sample ID: 2023-10-11-18
DIME Test ID: 2023-10-11-18-9
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D7741-11ε1: Standard Test Method for Measurement of Apparent Viscosity of Asphalt-Rubber or Other Asphalt Binders by Using a Rotational Handheld Viscometer (Viscosity)
Test Release Date: 2023-10-23
Test Results
Unit system used?: US Units
Input Type: Calculated
Tester's full name: Esther Foo
Date of test: 10/11/2023
Test Temperature: 375 F
Average Viscosity: 2300.0
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): tested at field
Test was verified on 10/23/2023 ✔