Summary for Test 2023-08-15-85-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 994812
DEA: 042K7204
EFIS: 0417000014
DIST-CO-RTE-PM04-CC-4-R14.3/24.3
Award Date03/23/2023
Closeout Date10/06/2025
Work DescriptionPvmt rehabilitation, slab repl, ADA curb ramp and install guardrail.
Location DescriptionOn state highway in Contra Costa County in and near Concord and Pittsburg from 0.3 miles east of Peralta Road Undercrossing to Loveridge Road Overcrossing.
QA Service Level1 (Verified on 05/10/2023)

Sample Information

Sample Taken Date08/15/2023 Sample Unique Key85
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/18/2023
Sample typeQuality Assurance A brief description of the samplePCC Beams
The quantity of what the sample constitutes3 PCC Beams From where was the sample collectedJob Site
First name of sampler or witnessed byNick Last name of sampler or witnessed byHall
Title of sampler Telephone number of sampler7072999133
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVanguard Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberHE4x4BM
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedNone
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-08-15-85
DIME Test ID: 2023-08-15-85-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2023-10-23

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Stress
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: Yes
Is a beam dimensional correction factor used?: Yes
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 08/18/2023
Identification number: Con_23_1003
Width of specimen: 6 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6 inch
Depth of specimen: 6 inch
Depth of specimen 2: 6 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum recording: 770 psi
Maximum recording 2: 800 psi
Maximum recording 3: 780 psi
Correction Factor: 1
Correction Factor 2: 1
Correction Factor 3: 1
Cap thickness: 0 inch
Curing history and apparent moisture condition of the specimen: Bath/moist
If specimen was capped, ground or if leather shims were used: yes
Defects in specimen, including numbers of beams discarded during test: none
Age of specimen: 3 days
Age of specimen in hours: 72 hours
Modulus of rupture: 770 psi
Modulus of rupture 2: 800 psi
Modulus of rupture 3: 780 psi
Modulus of rupture average: 780 psi
General comments (publicly viewable) (Max 1000 characters): All Beams PASSED

Test was verified on 10/23/2023