Summary for Test 2023-09-01-94-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 215396 DEA: 042K8404 EFIS: 0417000031 |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-29,80-0.0,0.8/1.6 |
| Award Date | 03/26/2021 |
| Closeout Date | 02/16/2024 |
| Work Description | HMA, STRUCTURAL CONCRETE, CIDH PILING AND REBAR. |
| Location Description | SOLANO COUNTY IN VALLEJO AT ROUTE 80/29 SEPARATION AND ON ROUTE 80 FROM 0.2 MILE NORTH OF CARQUINEZ BRIDGE TOLL PLAZA TO 0.3 MILE SOUTH OF MAGAZINE STREET OVERCROSSING |
| QA Service Level | 1 (Verified on 01/25/2021) |
Sample Information
| Sample Taken Date | 09/01/2023 | Sample Unique Key | 94 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/07/2023 |
| Sample type | Quality Assurance | A brief description of the sample | 1/2-INCH RHMA-O |
| The quantity of what the sample constitutes | LOT 1 SUBLOT 1 | From where was the sample collected | Source |
| First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | Hall |
| Title of sampler | Telephone number of sampler | 7072999133 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulcan Vallejo Batch Plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | OGFC |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | 326127 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-09-01-94
DIME Test ID: 2023-09-01-94-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-10-19
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 09/07/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1715.3 g
Mass Loss: 157.8 g
Correction Factor (Percent by mass of HMA Specimen): 7.84 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.17 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 1.19 %
General comments (publicly viewable) (Max 1000 characters): Vulcan Vallejo Batch Plant
LOT 1 SUBLOT 1
Test PASSED
Test was verified on 10/19/2023 ✔