Summary for Test 2023-10-17-28-2
Test performed: AASHTO T209-22Project Information
| Project Identifiers | Project ID: 995257 DEA: 09401004 EFIS: 0924000007 |
|---|---|
| DIST-CO-RTE-PM | 09-INY-190-9.8-68.0 |
| Award Date | 08/21/2023 |
| Closeout Date | 03/13/2025 |
| Work Description | Emergency Repair from Flood Damage to State Route 190 near Olancha, CA. |
| Location Description | State Route 190 |
| QA Service Level | 1 (Verified on 10/19/2023) |
Sample Information
| Sample Taken Date | 10/17/2023 | Sample Unique Key | 28 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/18/2023 | Sample type | Department Acceptance |
| A brief description of the sample | 3/4" HMA WMA | The quantity of what the sample constitutes | 1 Box of HMA |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Brian |
| Last name of sampler or witnessed by | Young | Title of sampler | TET |
| Telephone number of sampler | 7609208859 | Laboratory sample identification | HMA-01 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Fisher Sand and Gravel | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-10-17-28
DIME Test ID: 2023-10-17-28-2
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-10-19
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 10/19/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7310.5 grams
Mass of oven-dry sample in air for Sample 1: 2474.5 grams
Mass of container filled with the sample and water for Sample 1: 8792.4 grams
Temperature of Water: 76.8 °F
Specific Gravity for Sample 1: 2.493
Theoretical maximum density at 25°C (77°F): 155.2 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): HMA-01
Test was verified on 10/19/2023 ✔