Summary for Test 2023-09-26-28-6

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 994593
DEA: 081M1804
EFIS: 0821000087
DIST-CO-RTE-PM08-RIV-10,74,79,86,111,243-Var
Award Date05/09/2023
Closeout Date08/30/2024
Work DescriptionPOLYESTER CONCRETE AND HOT MIX ASPHALT OVERLAY.
Location DescriptionRIVERSIDE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 07/14/2023)

Sample Information

Sample Taken Date09/26/2023 Sample Unique Key28
Date that the sample was received by the laboratory/organization performing the testing09/28/2023 Sample typeVerification
A brief description of the sampleJJMF 3/4" HMA-A r24, 0.25% EVO The quantity of what the sample constitutes12 Bags Of Bin Agg. 3 Bags Of Rap 1 Bag MF
From where was the sample collectedManufacturer First name of sampler or witnessed byHector
Last name of sampler or witnessed byReyes Title of sampler
Telephone number of sampler Laboratory sample identification0500A-23
Linked DIME Sample ID The fabricator/manufacturer/facility nameMartin Marieta Coachella
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0084
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Martin Marietta Coachella
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number43417195 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-09-26-28
DIME Test ID: 2023-09-26-28-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2023-12-12

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 10/04/2023
Bulk dry specific gravity: 2.633
Average uncompacted voids: 48.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/12/2023 ✔