Summary for Test 2023-09-07-41-4

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 995087
DEA: 051P5904
EFIS: 0522000086
DIST-CO-RTE-PM05-SCR-1-0.0/5.0
Award DateNot set
Closeout DateNot set
Work DescriptionCold plane, RHMA-G
Location DescriptionWatsonville area, County line to Scenic pullout
QA Service Level1 (Verified on 08/21/2023)

Sample Information

Sample Taken Date09/07/2023 Sample Unique Key41
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing09/11/2023
Sample typeQuality Assurance A brief description of the sampleBWC Emulsion
The quantity of what the sample constitutes2 qt screw top container From where was the sample collectedJob Site
First name of sampler or witnessed byRichard Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID2023-09-07-24
The fabricator/manufacturer/facility nameWestern Emulsions Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeBWC
Lot NumberNot set Sub LotNot set

Test Details

DIME Sample ID: 2023-09-07-41
DIME Test ID: 2023-09-07-41-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Viscosity (Saybolt Furol) (Sec. 9))
Test Release Date: 2023-10-18

Test Results


Is Correction factor required?: Yes
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 10/18/2023
What temperature wil you be testing Saybolt Furol Viscosity?: 25 C
Certified Saybolt viscosity of the standard (Certified V): 149 sec
Efflux time for determination of the correction factor (ETCF1): 151.2 sec
Efflux time (t2) for determination of the correction factor (ETCF2): 151.6 sec
Correction Factor (F): 1.0 sec
Efflux time (ET) for test sample: 27.6 sec
Corrected efflux time as the Saybolt Furol viscosity (Corrected V): 28 sec
Test efflux temperature: 122 F
General comments (publicly viewable) (Max 1000 characters): Saybolt

Test was verified on 10/18/2023