Summary for Test 2023-09-05-40-4
Test performed: AASHTO T59-22Project Information
Project Identifiers | Project ID: 995087 DEA: 051P5904 EFIS: 0522000086 |
---|---|
DIST-CO-RTE-PM | 05-SCR-1-0.0/5.0 |
Award Date | 03/22/2023 |
Closeout Date | 08/13/2024 |
Work Description | Cold plane, RHMA-G |
Location Description | Watsonville area, County line to Scenic pullout |
QA Service Level | 1 (Verified on 08/21/2023) |
Sample Information
Sample Taken Date | 09/05/2023 | Sample Unique Key | 40 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 09/11/2023 |
Sample type | Quality Assurance | A brief description of the sample | BWC Emulsion |
The quantity of what the sample constitutes | 2 qt screw top container | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Richard | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | 2023-09-05-26 | |
The fabricator/manufacturer/facility name | Western Emulsions Irwindale | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphaltic Emulsion | Emulsion Grade | BWC |
---|---|---|---|
Lot Number | Not set | Sub Lot | Not set |
Dilution Percentage Rate | Not set |
Test Details
DIME Sample ID: 2023-09-05-40
DIME Test ID: 2023-09-05-40-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Viscosity (Saybolt Furol) (Sec. 9))
Test Release Date: 2023-10-18
Test Results
Is Correction factor required?: Yes
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 10/18/2023
What temperature wil you be testing Saybolt Furol Viscosity?: 25 C
Certified Saybolt viscosity of the standard (Certified V): 149 sec
Efflux time for determination of the correction factor (ETCF1): 151.2 sec
Efflux time (t2) for determination of the correction factor (ETCF2): 151.6 sec
Correction Factor (F): 1 sec
Efflux time (ET) for test sample: 32.2 sec
Corrected efflux time as the Saybolt Furol viscosity (Corrected V): 32 sec
Test efflux temperature: 122 F
General comments (publicly viewable) (Max 1000 characters): Saybolt
Test was verified on 10/18/2023 ✔