Summary for Test 2023-09-11-36-7

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 995087
DEA: 051P5904
EFIS: 0522000086
DIST-CO-RTE-PM05-SCR-1-0.0/5.0
Award Date03/22/2023
Closeout Date08/13/2024
Work DescriptionCold plane, RHMA-G
Location DescriptionWatsonville area, County line to Scenic pullout
QA Service Level1 (Verified on 08/21/2023)

Sample Information

Sample Taken Date09/11/2023 Sample Unique Key36
Date that the sample was received by the laboratory/organization performing the testing09/15/2023 Sample typeQuality Assurance
A brief description of the sampleBWC Emulsion The quantity of what the sample constitutes2 qt screw top container
From where was the sample collectedJob Site First name of sampler or witnessed byRichard
Last name of sampler or witnessed byQC Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameWestern Emulsions Irwindale
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeBWC
Lot NumberNot set Sub LotNot set
Dilution Percentage RateNot set

Test Details

DIME Sample ID: 2023-09-11-36
DIME Test ID: 2023-09-11-36-7
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Viscosity (Saybolt Furol) (Sec. 9))
Test Release Date: 2023-10-18

Test Results


Is Correction factor required?: Yes
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 10/18/2023
What temperature wil you be testing Saybolt Furol Viscosity?: 25 C
Certified Saybolt viscosity of the standard (Certified V): 149.0 sec
Efflux time for determination of the correction factor (ETCF1): 151.2 sec
Efflux time (t2) for determination of the correction factor (ETCF2): 151.6 sec
Correction Factor (F): 1.0 sec
Efflux time (ET) for test sample: 47.3 sec
Corrected efflux time as the Saybolt Furol viscosity (Corrected V): 47 sec
Test efflux temperature: 122 F
General comments (publicly viewable) (Max 1000 characters): Saybolt

Test was verified on 10/18/2023 ✔