Summary for Test 2023-09-12-92-9
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 993825 DEA: 040Q30U4 EFIS: 0420000235 COOP: 042830A3,042830A4 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA,CC-680-R11.0/R21.9,R0.0/R0.9 |
| Award Date | 11/23/2022 |
| Closeout Date | Not set |
| Work Description | PRECAST CONC PVMT, ELECTRONIC TOLL SYSTEM, JPCP, CB & STRUCTURAL CONC |
| Location Description | ALAMEDA AND CONTRA COSTA COUNTIES AT SUNOL AND IN SAN RAMON BETWEEN 0.4 MILE SOUTH OF CALAVERAS ROAD UNDERCROSSING TO 0.9 MILE NORTH OF ALCOSTA BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 05/11/2022) |
Sample Information
| Sample Taken Date | 09/12/2023 | Sample Unique Key | 92 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/13/2023 |
| Sample type | Quality Assurance | A brief description of the sample | Hot Mix Asphalt |
| The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Bhalinder | Last name of sampler or witnessed by | Pandher |
| Title of sampler | Assistant Resident Engineer | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Vulcan Pleasanton Plant | Transportation Laboratory (TL) Number | C0912014 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | LOT 1 SUBLOT 4 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 4 | HMA Mix Number | 220304 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-09-12-92
DIME Test ID: 2023-09-12-92-9
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-10-16
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Rob Lohman
Date of test: 09/27/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 2891.6 g
Mass of the specimen and specimen basket assembly prior to ignition: 5028.1 g
Mass of HMA Sample prior to ignition: 2136.5 g
Mass Loss: 129.7 g
Mass of aggregate remaining after ignition: 2006.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.74 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 5.19 %
General comments (publicly viewable) (Max 1000 characters): Lot 1 Sublot 5
Test was verified on 10/16/2023 ✔