Summary for Test 2017-03-01-5-1
Test performed: ASTM A615-15Project Information
| Project Identifiers | Project ID: 210735 DEA: 071193U4 EFIS: 0713000007 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-10-37.2/42.4 |
| Award Date | 11/16/2015 |
| Closeout Date | 07/11/2022 |
| Work Description | CONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS. |
| Location Description | IN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA |
| QA Service Level | 1 (Verified on 03/07/2016) |
Sample Information
| Sample Taken Date | 03/01/2017 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/14/2017 |
| Sample type | Quality Assurance | A brief description of the sample | A615 Grade 75 Threaded Bar |
| The quantity of what the sample constitutes | 6 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | ED | Last name of sampler or witnessed by | Leach |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | DSI Gerdau | Transportation Laboratory (TL) Number | C874426 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S3802417 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
| Threaded Bar Type | Deformed | Rebar Size | 8 |
| Nut Specification for Threaded Bar | A519 | System Manufacturer | DSI |
| Epoxy Coating Color | NA | Threaded Bar Application | Threaded Bar |
| Coating Standards | Uncoated | Bar Heat Number(s) | 6214274402, 6214274502, 6214303103, 621430460 |
| Nut Heat Number(s) | 00A164230 | Bar Lot Number | Unknown |
| Nut Lot Number | Unknown | Coupler Heat Number(s) | Unknown |
| Coupler Grade | Unknown |
Test Details
DIME Sample ID: 2017-03-01-5
DIME Test ID: 2017-03-01-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2017-03-24
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 03/17/2017
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1 | #8 Bar Heat #6214274502, Nut Heat #00A164230 | S3802417 | 0.79 | 109522 | 77017 | 16.8 | A615 Bar & Nut | Fred |
General comments (publicly viewable) (Max 1000 characters): A615 Bar & Nut
Test Graph
Source: Partner Data Point FileTest was verified on 3/17/2017 ✔