Summary for Test 2023-10-12-7-2

Test performed: CTM 231-March 2013

Project Information

Project IdentifiersProject ID: 994296
EFIS: 0716000375
DIST-CO-RTE-PM07-VEN-118-R1.4/1.8
Award Date12/07/2022
Closeout Date01/21/2026
Work DescriptionCONSTRUCT STORMWATER TREATMENT DEVICES.
Location DescriptionIN VENTURA COUNTY NEAR SATICOY FROM 0.2 MILE EAST OF NARDO STREET TO 0.1 MILE WEST OF SANTA CLARA RIVER
QA Service Level1 (Verified on 10/06/2022)

Sample Information

Sample Taken Date10/12/2023 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/12/2023
Sample typeDepartment Acceptance A brief description of the sampleSubgrade
The quantity of what the sample constitutes77 sq. yd. From where was the sample collectedJob Site
First name of sampler or witnessed byPhilip Last name of sampler or witnessed byMaquiran
Title of sampler Telephone number of sampler(213) 358-1518
Laboratory sample identification23-1650 Linked DIME Sample ID
The fabricator/manufacturer/facility nameBeador Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedFrom various locations at subgrade.
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2023-10-12-7
DIME Test ID: 2023-10-12-7-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-10-12

Test Results


Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: Phillip Maquiran
Date of test: 10/12/2023
Sum of Count or Density: 6.49 g/cc
Average of Count or Density: 2.16 g/cc
Sum of Moisture Count: 0.4 g/cc
Average of Moisture Count: 0.13 g/cc
Calculated Percent Relative Compaction: 94.7 %
Reported Percent Relative Compaction: 95 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/12/2023