Summary for Test 2023-09-26-58-1

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 994834
DEA: 010L4804
EFIS: 0122000021
DIST-CO-RTE-PM01-MEN-162-28.6/29.4
Award Date07/19/2023
Closeout Date06/11/2024
Work DescriptionRUBBERIZED SPEED HUMP, SOLAR LIGHTING ASSEMBLY SYSTEM, MINOR CONCRETE
Location DescriptionMENDOCINO COUNTY NEAR COVELO FROM 0.1 MILE WEST OF TOWN CREEK BRIDGE TO 0.1 MILE EAST OF EAST LANE ROAD
QA Service Level1 (Verified on 09/12/2023)

Sample Information

Sample Taken Date09/26/2023 Sample Unique Key58
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/12/2023
Sample typeQuality Assurance A brief description of the sampleF1554 Grade 55 HDG Anchor Bolts
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byRolondo Last name of sampler or witnessed byDavid
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePortland Bolt Manufacturing Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)3120830 Nut Mfg. Lot Number(s)W000037270
Washer Mfg. Lot Number(s)0723-802 Bolt SpecificationASTM 1554 Gr 55
Bolt Length(s)36" x 4" Nut SpecificationA563 HDG
Washer SpecificationA436 HDG FinishHot Dip Galvanized
Diameter/Size1 Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s)

Test Details

DIME Sample ID: 2023-09-26-58
DIME Test ID: 2023-09-26-58-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-10-13

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 10/12/2023
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1198068Proof Load

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 10/13/2023