Summary for Test 2017-03-02-6-4
Test performed: ASTM D2628-91-re11-highProject Information
| Project Identifiers | Project ID: 8196 DEA: 59912684 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | |
| Location Description | |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 03/02/2017 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/03/2017 | Sample type | Quality Assurance |
| A brief description of the sample | Joint Seal | The quantity of what the sample constitutes | 600ft |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Simon | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | D S Brown |
| Transportation Laboratory (TL) Number | NA | Inspector Lot Number from the Transportation Laboratory (TL) Form | NA |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM2 - Type B Elastomeric Joint Seal | Mfg. Lot Number(s) | 0317154 |
|---|---|---|---|
| Manufacturer(s) | D S Brown | Temperature | 72 |
| Humidity | 50 | Comments | Unknown |
| Joint Seal Size | 5" |
Test Details
DIME Sample ID: 2017-03-02-6
DIME Test ID: 2017-03-02-6-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D2628-91-re11-high: Standard Specification for Preformed Polychloroprene Elastomeric Joint Seals for Concrete Pavements (High Temp Recovery)
Test Release Date: 2017-03-28
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 03/16/2017
Temperature: 212 f
Humidity: 47 %
High Temp Recovery (70 hrs at 212F) Size Before (Height of Contact Face ): 5 in
High Temp Recovery (70 hrs at 212F) Size After (Expanded Contact Face ): 4.85 in
Percent Recovery (High Temp): 97 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/21/2017 ✔