Summary for Test 2023-10-10-8-4
Test performed: ASME B1.2-83r17Project Information
| Project Identifiers | Project ID: 993788 DEA: 033F0724 EFIS: 0322000010 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC-51-2.5/3.3 |
| Award Date | 04/22/2022 |
| Closeout Date | 08/09/2024 |
| Work Description | Procure steel girders |
| Location Description | District-County-Route-Post Mile: 03-Sac-51-2.5/3.3 |
| QA Service Level | 1 (Verified on 04/25/2022) |
Sample Information
| Sample Taken Date | 10/10/2023 | Sample Unique Key | 8 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/11/2023 | Sample type | Verification |
| A brief description of the sample | 1" A325 HDG fastener assemblies | The quantity of what the sample constitutes | 9 pcs |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Sebastian | Title of sampler | QAI |
| Telephone number of sampler | 760-908-79-39 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vigor Works | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | B398-060-23 | |
| Structure unique identifier | 03-3F0724 | Structure name | American River Bridge |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0171416 |
|---|---|---|---|
| Heat Number(s) | 10846500-226829-20863870 | Nut Mfg. Lot Number(s) | 23-41-005 |
| Washer Mfg. Lot Number(s) | E4193 | Bolt Specification | A325 |
| Bolt Length(s) | 3 1/2 " | Nut Specification | A563-DH |
| Washer Specification | F436-1 | Finish | A153 HDG |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | BG2596 |
| Rocap Test Requirement(s) | ASTM F3125 | Lubricant Requirements(s) | |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2023-10-10-8
DIME Test ID: 2023-10-10-8-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r17: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Test Release Date: 2023-10-11
Test Results
Input Type: Calculated
Tester's full name: Andrew Auvinen
Date of test: 10/11/2023
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 23-41-005
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: DH DMC
Size: 1 in
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/11/2023 ✔