Summary for Test 2023-09-21-80-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 994785
DEA: 023H32U4
EFIS: 0221000164
DIST-CO-RTE-PM02-SIS-I5-2.5/R15.9
Award Date04/28/2023
Closeout DateNot set
Work DescriptionRoadway rehabilitation and bridge improvements along I5 in Mount Shasta
Location DescriptionSIS I5 2.5/R15.9
QA Service Level1 (Verified on 05/03/2023)

Sample Information

Sample Taken Date09/21/2023 Sample Unique Key80
Date that the sample was received by the laboratory/organization performing the testing10/10/2023 Sample typeQuality Assurance
A brief description of the sample Dayton Superior coupler The quantity of what the sample constitutes4
From where was the sample collectedManufacturer First name of sampler or witnessed byMike
Last name of sampler or witnessed bySears Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameComblin Steel
Transportation Laboratory (TL) Numberc778604 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerDayton Superiour
Coupler ManufacturerBarlock Intermediate Assembler or Fabricator
Rebar Size#9 Coupler ModelBar-Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)4000003595 Rebar Heat Number(s)2310734
Rebar Size 2 Coupler Unique IDSL-17-01

Test Details

DIME Sample ID: 2023-09-21-80
DIME Test ID: 2023-09-21-80-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2023-10-12

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 10/10/2023
UTM: 400kip
Temperature: 72.00 f
Halo ID: Small
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11No. 9/29mm10.004719029190291Service Spliceaauvinen

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 10/12/2023 ✔