Summary for Test 2023-10-03-13-1
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 77777 DEA: CHEM-STOCK EFIS: CHEM-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 10/03/2023 | Sample Unique Key | 13 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/09/2023 |
| Sample type | Verification | A brief description of the sample | Double End Stud Anchor Bolt |
| The quantity of what the sample constitutes | 276 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | EDWARD | Last name of sampler or witnessed by | LEACH |
| Title of sampler | QA | Telephone number of sampler | 7072903887 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | A&M Bolt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 3123360, 8000015546, 122538 | Nut Mfg. Lot Number(s) | W000013561 |
| Washer Mfg. Lot Number(s) | E3214 | Bolt Specification | ASTM F1554 Gr. 55 |
| Bolt Length(s) | 36 | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 1 | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2023-10-03-13
DIME Test ID: 2023-10-03-13-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-10-12
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 10/10/2023
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 97624 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 10/12/2023 ✔