Summary for Test 2023-08-18-61-3
Test performed: ASTM D638-Dec14Project Information
| Project Identifiers | Project ID: 994549 DEA: 032G5204 EFIS: 0321000235 |
|---|---|
| DIST-CO-RTE-PM | 03-NEV,PLA,SIE-20,49,80-VAR |
| Award Date | 05/22/2023 |
| Closeout Date | 05/03/2024 |
| Work Description | PLACE POLYESTER CONCRETE OVERLAY AND REPLACE JOINT SEALS. |
| Location Description | NEVADA, PLACER AND SIERRA COUNTIES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 05/15/2023) |
Sample Information
| Sample Taken Date | 08/18/2023 | Sample Unique Key | 61 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/18/2023 |
| Sample type | Quality Control | A brief description of the sample | 1 gallon can / 9800 RESIN |
| The quantity of what the sample constitutes | 21 Totes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Gilberto | Last name of sampler or witnessed by | Gonzalez |
| Title of sampler | Quality Control Manager | Telephone number of sampler | 17076245467 |
| Laboratory sample identification | 943824 | Linked DIME Sample ID | 943824 |
| The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Polyester | Mfg. Lot Number(s) | 1464214 |
|---|---|---|---|
| Batch number | 1464214 | Mix number | 1464214 |
Test Details
DIME Sample ID: 2023-08-18-61
DIME Test ID: 2023-08-18-61-3
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Test Release Date: 2023-10-09
Test Results
Number of specimens tested: 6
Input Type: Measured
Tester's full name: Linda Bergstrom
Date of test: 05/25/2023
Conditioning procedure: 18/25/50+5/70
Speed of testing: 0.45 in/min
Sample 1 Width: 0.488 in
Sample 1 Thickness: 0.247 in
Sample 1 Area: 0.1205 in^2
Sample 1 Ultimate Strength Actual: 1000 lbs
Sample 1 percent elongation: 26.2 %
Sample 1 Time: 0 MM:SS
Sample 2 Width: 0.488 in
Sample 2 Thickness: 0.25 in
Sample 2 Area: 0.122 in^2
Sample 2 Ultimate Strength Actual: 1009 lbs
Sample 2 percent elongation: 18.1 %
Sample 2 Time: 0 MM:SS
Sample 3 Width: 0.489 in
Sample 3 Thickness: 0.25 in
Sample 3 Area: 0.1223 in^2
Sample 3 Ultimate Strength Actual: 1015 lbs
Sample 3 percent elongation: 16.3 %
Sample 3 Time: 0 MM:SS
Sample 4 Width: 0.489 in
Sample 4 Thickness: 0.251 in
Sample 4 Area: 0.1227 in^2
Sample 4 Ultimate Strength Actual: 1016 lbs
Sample 4 percent elongation: 17.1 %
Sample 4 Time: 0 MM:SS
Sample 5 Width: 0.488 in
Sample 5 Thickness: 0.251 in
Sample 5 Area: 0.1225 in^2
Sample 5 Ultimate Strength Actual: 1021 lbs
Sample 5 percent elongation: 13.2 %
Sample 5 Time: 0 MM:SS
Sample 6 Width: 0.488 in
Sample 6 Thickness: 0.252 in
Sample 6 Area: 0.123 in^2
Sample 6 Ultimate Strength Actual: 1027 lbs
Sample 6 percent elongation: 27.2 %
Sample 6 Time: 0 MM:SS
Sample 1 Ultimate strength: 8298.8 psi
Sample 2 Ultimate strength : 8270.5 psi
Sample 3 Ultimate strength: 8299.3 psi
Sample 4 Ultimate strength: 8280.4 psi
Sample 5 Ultimate strength: 8334.7 psi
Sample 6 Ultimate strength : 8349.6 psi
Ultimate Strength Average: 8306 psi
Percent Elongation Average: 20 %
General comments (publicly viewable) (Max 1000 characters): Accepted vendor's results.
Test was verified on 10/9/2023 ✔