Summary for Test 2023-08-18-71-1
Test performed: CONCLP 4-16Project Information
| Project Identifiers | Project ID: 994612 DEA: 112N1414 EFIS: 1121000253 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-15,78-Various |
| Award Date | 05/26/2023 |
| Closeout Date | 09/26/2024 |
| Work Description | PLACE METHACRYLATE, POLYESTER CONCRETE, JOINT SEALS AND REPAIR SPALLS. |
| Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 08/22/2023) |
Sample Information
| Sample Taken Date | 08/18/2023 | Sample Unique Key | 71 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/18/2023 |
| Sample type | Quality Control | A brief description of the sample | 2 pints 204/CHP/8020 |
| The quantity of what the sample constitutes | 100 Totes | From where was the sample collected | Source |
| First name of sampler or witnessed by | Gilberto | Last name of sampler or witnessed by | Gonzalez |
| Title of sampler | Quality Control Manager | Telephone number of sampler | 17076245467 |
| Laboratory sample identification | 000001 | Linked DIME Sample ID | 000001 |
| The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia | Transportation Laboratory (TL) Number | Sacramento Caltrans lab |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Methacrylate | Mfg. Lot Number(s) | 2390591690 |
|---|---|---|---|
| Batch number | 2390591690 | Mix number | 2390591690 |
Test Details
DIME Sample ID: 2023-08-18-71
DIME Test ID: 2023-08-18-71-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2023-10-02
Test Results
Input Type: Measured
Tester's full name: Rachael Chavez
Date of test: 09/28/2023
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 19.7
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 9
Volatile content (ASTM D 2369) 30% max: 11.1
Flash point (ASTM D 3828) more than 180 deg F: 190
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 910.484
Tack free time, 400 minutes max: 329
General comments (publicly viewable) (Max 1000 characters): CA551 and tack free time accepted based on vendor's results
Test was verified on 10/2/2023 ✔