Summary for Test 2023-09-29-16-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 214486 DEA: 080K1224 EFIS: 0815000244 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-R28.6/37.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | REHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT |
Location Description | SAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
Sample Taken Date | 09/29/2023 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/29/2023 |
Sample type | Quality Assurance | A brief description of the sample | Soil |
The quantity of what the sample constitutes | 18000SQF | From where was the sample collected | Job Site |
First name of sampler or witnessed by | NATHAN | Last name of sampler or witnessed by | OGBASELIASIE |
Title of sampler | te | Telephone number of sampler | |
Laboratory sample identification | 92923 TEST 01 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | AT THE JOBSITE | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-09-29-16
DIME Test ID: 2023-09-29-16-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-10-02
Test Results
Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: NATHAN OGBASELIASIE
Date of test: 09/29/2023
Gage No.: 33197
Test No.: 1
Nuclear By: nathan ogbaseliasie
Non-Bias Plan No.: 5
Depth: 7
Material No.: CLASS II BASE/
Material Type: AGGREGATE BASE
Impact By: nathan ogbaseliasie
Standard Count Density: 1828 g/cc
Count or Density 1: 945 g/cc
Count or Density 2: 1100 g/cc
Count or Density 3: 1178 g/cc
Count or Density 4: 1164 g/cc
Count or Density 5: 1095 g/cc
Standard Count Moisture: 583 g/cc
Moisture Count 1: 141 g/cc
Moisture Count 2: 141 g/cc
Moisture Count 3: 72 g/cc
Moisture Count 4: 83 g/cc
Moisture Count 5: 67 g/cc
Sum of Count or Density: 5482.00 g/cc
Average of Count or Density: 1096.00 g/cc
Sum of Moisture Count: 504.00 g/cc
Average of Moisture Count: 101.00 g/cc
Count Ratio Density: 0.60
Count Ratio Moisture: 0.17
Calculated Percent Relative Compaction: 97.3 %
Reported Percent Relative Compaction: 97 %
General comments (publicly viewable) (Max 1000 characters): DENSITY SPEC 95%
Test was verified on 10/2/2023 ✔