Summary for Test 2023-09-06-68-4

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/06/2023 Sample Unique Key68
Date that the sample was received by the laboratory/organization performing the testing09/06/2023 Sample typeQuality Control
A brief description of the samplePG64-28M Modified Asphalt Binder The quantity of what the sample constitutes1 of 2 cans
From where was the sample collectedManufacturer First name of sampler or witnessed byJohn
Last name of sampler or witnessed byPartenan Title of sampler Sr Asphalt Technician
Telephone number of sampler6614327352 Laboratory sample identification6428230906
Linked DIME Sample ID The fabricator/manufacturer/facility nameSan Joaquin Refinery, Bakersfield, CA
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28 M
ModifiedYes Lot number6428230906
Sublot number Tank number5006
Time of sample7:20 am HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2023-09-06-68
DIME Test ID: 2023-09-06-68-4
Testing Lab: San Joaquin Refinery - Bakersfield
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2023-10-04

Test Results


Phase: RTFO residue
Input Type: Calculated
Tester's full name: John Partenan
Date of test: 09/06/2023
Phase Angle (δ) (for the 10 cycles): 71.3 degree
Dynamic Shear, G*/sin(δ): 2.26 kPa
General comments (publicly viewable) (Max 1000 characters): test @64.0f

Test was verified on 10/4/2023 ✔