Summary for Test 2023-09-13-48-3

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 995105
DEA: 023J8104
EFIS: 0222000086
DIST-CO-RTE-PM02-SIS-3-0.408/7.1
Award Date03/17/2023
Closeout Date04/11/2024
Work DescriptionScott Mountain Overlay
Location DescriptionNot set
QA Service Level1 (Verified on 08/24/2023)

Sample Information

Sample Taken Date09/13/2023 Sample Unique Key48
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/14/2023
Sample typeProduction Start-Up A brief description of the sampleUntreated 1/2-inch Aggregate
The quantity of what the sample constitutesProduction Start Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byJoe Last name of sampler or witnessed byDelgado
Title of samplerConsultant Telephone number of sampler
Laboratory sample identificationD79346F Linked DIME Sample ID
The fabricator/manufacturer/facility nameTullis - Northstate Asphalt (Redding, CA) Transportation Laboratory (TL) Number815625
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0057::Shasta Ranch Aggregates (Anderson, CA)
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedLaboratory Batched from Untreated Sized Virgin Aggregate Stockpile Samples
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-09-13-48
DIME Test ID: 2023-09-13-48-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2023-10-02

Test Results


Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 09/26/2023
Mass of saturated surface dry sample (before pycnometer) (S): 501.3 grams
Mass of the pycnometer with water and aggregate (C): 961.9 grams
Mass of the pycnometer with water (B): 652.7 grams
Mass of the oven dried sample (before pycnometer) (A): 483.9 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 501.3 grams
Mass of the oven dry aggregate (for absorption) (A): 483.9 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.519
Bulk specific gravity (SSD Basis): 2.610
Apparent specific gravity: 2.770
Absorption: 3.6 %
General comments (publicly viewable) (Max 1000 characters): Gsbvf(unwashed)=2.519

Test was verified on 10/2/2023