Summary for Test 2023-09-15-49-1

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 994845
DEA: 061E6104
EFIS: 0622000068
DIST-CO-RTE-PM06-TUL-63-2.0/4.0
Award Date04/06/2023
Closeout Date02/26/2024
Work DescriptionFOR CONSTRUCTION ON STATE HIGHWAY IN TULARE COUNTY NEAR VISALIA FROM EAST CARTMILL AVENUE TO AVENUE 264
Location DescriptionIn District 06 On Route 63
QA Service Level1 (Verified on 06/14/2023)

Sample Information

Sample Taken Date09/15/2023 Sample Unique Key49
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/21/2023
Sample typeQuality Assurance A brief description of the samplePMCRS-2h Emulsion
The quantity of what the sample constitutes1 jug From where was the sample collectedJob Site
First name of sampler or witnessed byG. Last name of sampler or witnessed byMohsen
Title of samplerARE Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTalley Oil Transportation Laboratory (TL) Number056433
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphaltic Emulsion Emulsion GradePMCRS-2h
Lot NumberNot set Sub LotNot set

Test Details

DIME Sample ID: 2023-09-15-49
DIME Test ID: 2023-09-15-49-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2023-09-27

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Humberto Ramirez
Date of test: 09/25/2023
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 144.4 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 111.9 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 145.1 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 113.0 g
Beaker 1 Residue: 65.0 %
Beaker 2 Residue: 64.2 %
Percentage of residue: 65 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/27/2023