Summary for Test 2017-02-09-5-2

Test performed: ASTM E23-12c

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date02/09/2017 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing02/17/2017 Sample typeQuality Assurance
A brief description of the sampleA709 Steel Check Sample The quantity of what the sample constitutes1
From where was the sample collectedFabricator First name of sampler or witnessed byJoe
Last name of sampler or witnessed byLanz Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameStinger Bridge Iron
Transportation Laboratory (TL) NumberC952663 Inspector Lot Number from the Transportation Laboratory (TL) FormL10600517
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM6 - Steel Check Sample Plate Heat Number(s)U8199
Material SpecificationA709 GradeHPS 50W
Thickness3.25 ShapeSquare
Metal Foundry Manufacturer (Mill)Arcelormittal Plate Plate Dimension12 x 12

Test Details

DIME Sample ID: 2017-02-09-5
DIME Test ID: 2017-02-09-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Test Release Date: 2017-03-08

Test Results


Input Type: Measured
Tester's full name: Brian Ewing
Date of test: 02/27/2017
Temperature Required: 10 oF
Minimum Energy Required: 30 ftlb
Test Temperature 1: 10.9 oF
Impact Energy 1: 253 ftlb
Impact Energy 2: 286 ftlb
Impact Energy 3: 285 ftlb
Striker Radius: 8 mm
Average Impact Energy: 275 ftlb
Value Exceeds The Machine Capacity?: No
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/1/2017 ✔