Summary for Test 2023-09-18-61-8
Test performed: AASHTO T209-22Project Information
| Project Identifiers | Project ID: 994617 DEA: 112N1664 EFIS: 1122000153 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-79-44.7/53.0 |
| Award Date | 05/18/2023 |
| Closeout Date | 06/11/2024 |
| Work Description | COLD PLANE, RHMA OVERLAY, PAVEMENT MARKING, & RUMBLE STRIP. |
| Location Description | SAN DIEGO COUNTY NEAR SUNSHINE SUMMIT FROM 1.2 MILES NORTH OF ACORN CREEK BRIDGE TO RIVERSIDE COUNTY LINE |
| QA Service Level | 1 (Verified on 11/30/2023) |
Sample Information
| Sample Taken Date | 09/18/2023 | Sample Unique Key | 61 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/19/2023 | Sample type | Quality Assurance |
| A brief description of the sample | 3/4" HMA PSU | The quantity of what the sample constitutes | 12 boxes 3 bags |
| From where was the sample collected | Source | First name of sampler or witnessed by | N/A |
| Last name of sampler or witnessed by | N/A | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 9601-PSU | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Martin Marietta | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 53417105 | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-09-18-61
DIME Test ID: 2023-09-18-61-8
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-10-03
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 09/29/2023
Method Performed: no data
Mass of container filled with water 1: 7477.1 grams
Mass of oven-dry sample in air for Sample 1: 1581.4 grams
Mass of container filled with the sample and water for Sample 1: 8435.9 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.540
Theoretical maximum density at 25°C (77°F): 158.1 lb/ft^3
General comments (publicly viewable) (Max 1000 characters): RAP Rice
Test was verified on 10/3/2023 ✔