Summary for Test 2023-09-18-62-7

Test performed: AASHTO T96-02r10

Project Information

Project IdentifiersProject ID: 994617
DEA: 112N1664
EFIS: 1122000153
DIST-CO-RTE-PM11-SD-79-44.7/53.0
Award Date05/18/2023
Closeout Date06/11/2024
Work DescriptionCOLD PLANE, RHMA OVERLAY, PAVEMENT MARKING, & RUMBLE STRIP.
Location DescriptionSAN DIEGO COUNTY NEAR SUNSHINE SUMMIT FROM 1.2 MILES NORTH OF ACORN CREEK BRIDGE TO RIVERSIDE COUNTY LINE
QA Service Level1 (Verified on 11/30/2023)

Sample Information

Sample Taken Date09/18/2023 Sample Unique Key62
Date that the sample was received by the laboratory/organization performing the testing09/19/2023 Sample typeQuality Assurance
A brief description of the sample3/4" HMA PSU The quantity of what the sample constitutes12 boxes 3 bags
From where was the sample collectedSource First name of sampler or witnessed byN/A
Last name of sampler or witnessed byN/A Title of sampler
Telephone number of sampler Laboratory sample identification9601-PSU
Linked DIME Sample ID The fabricator/manufacturer/facility nameMartin Marietta
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)N/A
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-09-18-62
DIME Test ID: 2023-09-18-62-7
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2023-10-03

Test Results


Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 09/29/2023
Grading designation: B
Mass of sample (before test): 5000 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4856 grams
Mass of sample on No.12 sieve (after 500 revolutions): 4353 grams
Percent loss after 100 revolutions: 3 %
Percent loss after 500 revolutions: 13 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/3/2023 ✔