Summary for Test 2017-02-13-3-1

Test performed: CONCLP 3-16

Project Information

Project IdentifiersProject ID: 208682
DEA: 083401U4
EFIS: 0800000609
DIST-CO-RTE-PM08-SBD-138,138-6.2/6.4,2.3/R15.2
Award Date09/10/2014
Closeout Date06/23/2021
Work DescriptionWIDEN TO 4 LNS FR BEEKLEY RD TO JCT 15, ADD 1 LN EB FR PHELAN RD TO
Location DescriptionSAN BERNARDINO COUNTY ON ROUTE 138 NEAR PHELAN FROM 0.6 MILE WEST OF PHELAN ROAD TO THE JUNCTION OF ROUTE 15 AND ON ROUTE 2 FROM 0.1 MILE NORTH OF WILD HORSE CANYON ROAD TO ROUTE 138
QA Service Level1 (Verified on 03/11/2013)

Sample Information

Sample Taken Date02/13/2017 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing01/11/2017 Sample typeQuality Assurance
A brief description of the samplepolyester resin The quantity of what the sample constitutes2 tankers
From where was the sample collectedManufacturer First name of sampler or witnessed byChris
Last name of sampler or witnessed bynanes Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identification17-011
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility namereichhold azusa
Transportation Laboratory (TL) Numberc594918 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1029883
Batch Number1029883 Mix number3225

Test Details

DIME Sample ID: 2017-02-13-3
DIME Test ID: 2017-02-13-3-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-05-25

Test Results


Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 02/20/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 105 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 51.4 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 2966 psi
Styrene ASTM D 2369 40% to 50 %: 46.8 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 0 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.5 grams
General comments (publicly viewable) (Max 1000 characters): accepted Q.C. CT551 results 519psi

Test was verified on 5/25/2017 ✔