Summary for Test 2017-02-13-3-1

Test performed: CONCLP 3-16

Project Information

Project IdentifiersProject ID: 208682
DEA: 083401U4
EFIS: 0800000609
DIST-CO-RTE-PM08-SBD-138,138-6.2/6.4,2.3/R15.2
Award Date09/10/2014
Closeout Date06/23/2021
Work DescriptionWIDEN TO 4 LNS FR BEEKLEY RD TO JCT 15, ADD 1 LN EB FR PHELAN RD TO
Location DescriptionSAN BERNARDINO COUNTY ON ROUTE 138 NEAR PHELAN FROM 0.6 MILE WEST OF PHELAN ROAD TO THE JUNCTION OF ROUTE 15 AND ON ROUTE 2 FROM 0.1 MILE NORTH OF WILD HORSE CANYON ROAD TO ROUTE 138
QA Service Level1 (Verified on 03/11/2013)

Sample Information

Sample Taken Date02/13/2017 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/11/2017
Sample typeQuality Assurance A brief description of the samplepolyester resin
The quantity of what the sample constitutes2 tankers From where was the sample collectedManufacturer
First name of sampler or witnessed byChris Last name of sampler or witnessed bynanes
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification17-011 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility namereichhold azusa Transportation Laboratory (TL) Numberc594918
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set Bid ItemNot set

Material Information

Material TypePolyester Mfg. Lot Number(s)1029883
Batch number1029883 Mix number3225

Test Details

DIME Sample ID: 2017-02-13-3
DIME Test ID: 2017-02-13-3-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 3-16: Polyester Resin
Test Release Date: 2017-05-25

Test Results


Input Type: Calculated
Tester's full name: Mike Mullins
Date of test: 02/20/2017
Viscosity ASTM D 2196, RVT, No. 1 spindle 75 to 200 cps @ 20 RPM, 77°F: 105 cps
Specific gravity ASTM D 1475 1.05 to 1.10 @ 77°F: 1.08
Conditioning (18/25/50 + 5/70) Elogation ASTM D 638, minimum 35%: 51.4 %
Tensile Strength ASTM D 638 Type 1 @ 0.45 in/min, minimum 2500 psi: 2966 psi
Styrene ASTM D 2369 40% to 50 %: 46.8 %
PCC - SSD bond strength CTM 551 500 psi minimun @ 24 hours: 0 psi
Static Volatile Emissions, SCAQMD 309-91, maximum loss 1.0 grams: 0.5 grams
General comments (publicly viewable) (Max 1000 characters): accepted Q.C. CT551 results 519psi

Test was verified on 5/25/2017