Summary for Test 2023-09-01-47-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 215396
DEA: 042K8404
EFIS: 0417000031
DIST-CO-RTE-PM04-SOL-29,80-0.0,0.8/1.6
Award Date03/26/2021
Closeout Date02/16/2024
Work DescriptionHMA, STRUCTURAL CONCRETE, CIDH PILING AND REBAR.
Location DescriptionSOLANO COUNTY IN VALLEJO AT ROUTE 80/29 SEPARATION AND ON ROUTE 80 FROM 0.2 MILE NORTH OF CARQUINEZ BRIDGE TOLL PLAZA TO 0.3 MILE SOUTH OF MAGAZINE STREET OVERCROSSING
QA Service Level1 (Verified on 01/25/2021)

Sample Information

Sample Taken Date09/01/2023 Sample Unique Key47
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/01/2023
Sample typeQuality Assurance A brief description of the sample3/4-INCH RHMA-G
The quantity of what the sample constitutesLOT 1 SUBLOT 1 From where was the sample collectedJob Site
First name of sampler or witnessed byNick Last name of sampler or witnessed byHall
Title of sampler Telephone number of sampler7072999133
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Pleasanton Drier Drum Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number1
Sublot number1 HMA Mix Number226108

Test Details

DIME Sample ID: 2023-09-01-47
DIME Test ID: 2023-09-01-47-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-09-22

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 09/01/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2016.5 g
Mass Loss: 175.5 g
Correction Factor (Percent by mass of HMA Specimen): 7.48 %
Moisture Content: 0 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 1.08 %
General comments (publicly viewable) (Max 1000 characters): LOT 1 SUBLOT 1 PASSED Vulcan Pleasanton Drier Drum Plant

Test was verified on 9/22/2023