Summary for Test 2023-09-07-55-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994620 DEA: 120T6304 EFIS: 1222000073 |
---|---|
DIST-CO-RTE-PM | 12-ORA-39-3.2/5.8 |
Award Date | 06/12/2023 |
Closeout Date | 06/18/2024 |
Work Description | COLD PLANE AC PVMT AND PLACE RHMA. |
Location Description | ORANGE COUNTY IN HUNTINGTON BEACH FROM ELLIS AVENUE/MAIN STREET TO STARK DRIVE |
QA Service Level | 1 (Verified on 07/07/2023) |
Sample Information
Sample Taken Date | 09/07/2023 | Sample Unique Key | 55 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/07/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1/2 RHMAG |
The quantity of what the sample constitutes | RHMAG, AGG | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jimmy | Last name of sampler or witnessed by | Pham |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 23-0905 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | RJ Noble Orange | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number |
Test Details
DIME Sample ID: 2023-09-07-55
DIME Test ID: 2023-09-07-55-1
Testing Lab: CT D12 - Huntington Beach Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-09-26
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: David Nguyen
Date of test: 09/21/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 4018.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 5522.7 g
Mass of HMA Sample prior to ignition: 1503.8 g
Mass Loss: 115.6 g
Mass of aggregate remaining after ignition: 1388.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.02 %
Moisture Content: 0 %
Temperature Compensation Factor: 0 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.67 %
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
2023AC-SP-0075 | 105.84 KB | 09/22/2023 | 2023-09-07-55-1 | Info |
Test was verified on 9/26/2023 ✔