Summary for Test 2023-09-13-57-1

Test performed: AASHTO T209-22

Project Information

Project IdentifiersProject ID: 214451
DEA: 07303704
EFIS: 0714000035
DIST-CO-RTE-PM07-LA-101-8.0/27.3
Award Date12/19/2019
Closeout Date05/07/2024
Work DescriptionREPLACE CONCRETE BARRIERS.
Location DescriptionTHE CITY AND COUNTY OF LOS ANGELES FROM PILGRIMAGE OVERCROSSING TO VALLEY CIRCLE BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 08/12/2020)

Sample Information

Sample Taken Date09/13/2023 Sample Unique Key57
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/15/2023
Sample typeDepartment Acceptance A brief description of the sample3/4" HMA-A 105793
The quantity of what the sample constitutes750 Tons From where was the sample collectedManufacturer
First name of sampler or witnessed byGerardo Last name of sampler or witnessed byZubieta
Title of samplerTEC Telephone number of sampler
Laboratory sample identification23-438 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA-Irwindale Transportation Laboratory (TL) Number924635
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number105793

Test Details

DIME Sample ID: 2023-09-13-57
DIME Test ID: 2023-09-13-57-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-09-21

Test Results


Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Chad Chotibhongs
Date of test: 09/18/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7359.3 grams
Mass of oven-dry sample in air for Sample 1: 2627.9 grams
Mass of container filled with the sample and water for Sample 1: 8950.8 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.536
Theoretical maximum density at 25°C (77°F): 157.9 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/21/2023