Summary for Test 2023-09-06-55-3

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 214627
DEA: 05344904
EFIS: 0500000505
DIST-CO-RTE-PM05-SBT-156-3/R8.2
Award Date05/19/2022
Closeout DateNot set
Work DescriptionSAN BENITO ROUTE 156 IMPROVEMENT PROJECT SAN BENITO RTE 156 IMPROVEMENT PROJECT; INCLUDES NEW BRIDGE AND WIDENING OF EXISTING BRIDGE.
Location DescriptionSAN BENITO COUNTY IN AND NEAR SAN JUAN BAUTISTA FROM THE ALAMEDA TO 0.2 MILE EAST OF FOURTH STREET/BUSINESS ROUTE 156
QA Service Level1 (Verified on 01/14/2020)

Sample Information

Sample Taken Date09/06/2023 Sample Unique Key55
Date that the sample was received by the laboratory/organization performing the testing09/15/2023 Sample typeDepartment Acceptance
A brief description of the sample1 can binder The quantity of what the sample constitutes1 Can
From where was the sample collectedSource First name of sampler or witnessed byA
Last name of sampler or witnessed byRomize Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameValero
Transportation Laboratory (TL) Number00000000000000 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-10
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2023-09-06-55
DIME Test ID: 2023-09-06-55-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2023-09-22

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Alonso Lopez-Sanchez
Date of test: 09/21/2023
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 18.058 kPa
Phase Angle (δ) (for the 10 cycles): 50.2 degree
Complex Modulus (G*) (for the 10 measurements): 1796.734 kPa
Test Temperature (Specimen 1): 31.0 C
(G*) x sin(δ)=: 1380 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 9/22/2023 ✔