Summary for Test 2023-08-14-84-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994613 DEA: 112N1444 EFIS: 1122000009 |
---|---|
DIST-CO-RTE-PM | 11-SD-52,125,805-VAR |
Award Date | 05/30/2023 |
Closeout Date | Not set |
Work Description | POLYESTER CONCRETE OVERLAY, METHACRYLATE, & JOINT SEALS. |
Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 07/18/2023) |
Sample Information
Sample Taken Date | 08/14/2023 | Sample Unique Key | 84 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/15/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1/2" HMA |
The quantity of what the sample constitutes | 12 boxes 3 bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Jesse | Last name of sampler or witnessed by | Fuentes |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 9201-PSU | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | CCA Lakeside | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | 21217005 |
Test Details
DIME Sample ID: 2023-08-14-84
DIME Test ID: 2023-08-14-84-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-10-10
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 09/19/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3967.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 5526.0 g
Mass of HMA Sample prior to ignition: 1558.1 g
Mass Loss: 95.1 g
Mass of aggregate remaining after ignition: 1463.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.73 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 5.37 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/10/2023 ✔