Summary for Test 2023-09-11-47-2

Test performed: AASHTO T316-17

Project Information

Project IdentifiersProject ID: 995147
DEA: 08321804
DIST-CO-RTE-PM08---
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 11/30/2023)

Sample Information

Sample Taken Date09/11/2023 Sample Unique Key47
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/14/2023
Sample typeProduction Start-Up A brief description of the samplePG Asphalt Binder
The quantity of what the sample constitutes1 Quart Can From where was the sample collectedSupplier
First name of sampler or witnessed byZubieta Tec Last name of sampler or witnessed byZubieta Tec
Title of sampler Telephone number of sampler
Laboratory sample identification0468-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAll American-Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2023-09-11-47
DIME Test ID: 2023-09-11-47-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2023-09-19

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 09/14/2023
Time of test: 08:50 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 84.0 %
Viscosity reading #1 (A) : 0.42 Pa-s
Viscosity reading #2 (B) : 0.425 Pa-s
Viscosity reading #3 (C): 0.425 Pa-s
Average viscosity: 0.423 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/19/2023