Summary for Test 2023-07-22-61-17

Test performed: CTM 226-July 2010

Project Information

Project IdentifiersProject ID: 994803
DEA: 043J0704
EFIS: 0415000077
DIST-CO-RTE-PM04-CC-80-10.1/13.5
Award Date03/10/2023
Closeout DateNot set
Work DescriptionRemove PCC and AC, place PCP and AC Resurfacing.
Location DescriptionConstruction on State Highway in Contra Costa County in Hercules and Crockett from Route 80/4 separation to 0.1 mile west of Crockett Viaduct.
QA Service Level1 (Verified on 05/10/2023)

Sample Information

Sample Taken Date07/22/2023 Sample Unique Key61
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/24/2023
Sample typeQuality Assurance A brief description of the sampleHE4x12BM Concrete Beams
The quantity of what the sample constitutes650-1300CY From where was the sample collectedJob Site
First name of sampler or witnessed byNick Last name of sampler or witnessed byHall
Title of sampler Telephone number of sampler7072999133
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCEMEX. Source Clayton#4402 Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)NONE
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberHE4x12BM Lot number
Sublot number Aggregate Mix NumberHE4x12BM

Test Details

DIME Sample ID: 2023-07-22-61
DIME Test ID: 2023-07-22-61-17
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying
Test Release Date: 2023-09-19

Test Results


Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 07/24/2023
Wet weight of the sample: 2006.0000000000 grams
Dry weight of the sample: 1988.0000000000 grams
Weight of water in sample: 2006.0000000000 grams
Percent moisture: 0.9 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/19/2023