Summary for Test 2023-09-13-43-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 995105 DEA: 023J8104 EFIS: 0222000086 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-3-0.408/7.1 |
| Award Date | 03/17/2023 |
| Closeout Date | 04/11/2024 |
| Work Description | Scott Mountain Overlay |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 08/24/2023) |
Sample Information
| Sample Taken Date | 09/13/2023 | Sample Unique Key | 43 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/13/2023 |
| Sample type | Production Start-Up | A brief description of the sample | 2 bags of Combined RAP (1/2-inch) |
| The quantity of what the sample constitutes | Production Start Up Evaluation | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Delgado |
| Title of sampler | Consultant | Telephone number of sampler | |
| Laboratory sample identification | D79342B | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Tullis Inc. - Northstate Asphalt (Redding CA) | Transportation Laboratory (TL) Number | 815623 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Tullis, Northstate Asphalt |
|---|---|---|---|
| Aggregate Size | 1/2-inch | Aggregate Source | |
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number |
Test Details
DIME Sample ID: 2023-09-13-43
DIME Test ID: 2023-09-13-43-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-09-26
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Joe Mishoe
Date of test: 09/14/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3108.5 g
Mass of the specimen and specimen basket assembly prior to ignition: 4736.0 g
Mass of HMA Sample prior to ignition: 1627.5 g
Mass Loss: 90.2 g
Mass of aggregate remaining after ignition: 1537.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.18 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.36 %
General comments (publicly viewable) (Max 1000 characters): Pbr(uncorrected)=5.36%
Test was verified on 9/26/2023 ✔