Summary for Test 2023-08-25-51-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995153
DEA: 051P7604
EFIS: 0522000104
DIST-CO-RTE-PM05---
Award Date03/06/2023
Closeout Date12/14/2023
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 09/15/2023)

Sample Information

Sample Taken Date08/25/2023 Sample Unique Key51
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/12/2023
Sample typeDispute Resolution A brief description of the sample1/2" RHMA-G
The quantity of what the sample constitutes2 Boxes, Aggregate, Binder From where was the sample collectedSource
First name of sampler or witnessed byIsaac Last name of sampler or witnessed byLarey-Chezem
Title of samplerTET Telephone number of sampler
Laboratory sample identification023-064 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSPM-Avenal Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number1
Sublot number11 HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2023-08-25-51
DIME Test ID: 2023-08-25-51-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-09-18

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Glenn Bradley
Date of test: 09/18/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 4199.8 g
Mass of the specimen and specimen basket assembly prior to ignition: 5869.3 g
Mass of HMA Sample prior to ignition: 1669.5 g
Mass Loss: 148.5 g
Mass of aggregate remaining after ignition: 1521.0 g
Correction Factor (Percent by mass of HMA Specimen): 1.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.21 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.68 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/18/2023