Summary for Test 2023-09-14-34-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995105
DEA: 023J8104
EFIS: 0222000086
DIST-CO-RTE-PM02-SIS-3-0.408/7.1
Award Date03/17/2023
Closeout Date04/11/2024
Work DescriptionScott Mountain Overlay
Location DescriptionNot set
QA Service Level1 (Verified on 08/24/2023)

Sample Information

Sample Taken Date09/14/2023 Sample Unique Key34
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/14/2023
Sample typeVerification A brief description of the sample1/2" HMA-A 25% RAP PG58-22 Valero
The quantity of what the sample constitutes2 Boxes From where was the sample collectedManufacturer
First name of sampler or witnessed byTerry Last name of sampler or witnessed byMcCormick
Title of samplerTET Telephone number of sampler
Laboratory sample identificationD79348 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTullis Inc. - Northstate Asphalt (Redding CA) Transportation Laboratory (TL) Number824476
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2023-09-14-34
DIME Test ID: 2023-09-14-34-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-09-28

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Colt Sweeny
Date of test: 09/14/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3108.4 g
Mass of the specimen and specimen basket assembly prior to ignition: 4733.2 g
Mass of HMA Sample prior to ignition: 1624.8 g
Mass Loss: 105.6 g
Mass of aggregate remaining after ignition: 1519.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.71 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.18 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.61 %
General comments (publicly viewable) (Max 1000 characters): Pb=5.60%

Test was verified on 9/28/2023