Summary for Test 2023-08-29-6-1

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 215620
DEA: 01436404
EFIS: 0100000193
DIST-CO-RTE-PM01-DN-101-35.8/36.5
Award Date07/11/2022
Closeout DateNot set
Work DescriptionDr. Fine Bridge Replacement
Location DescriptionDR. FINE BRIDGE REPLACEMENT FROM LAKE EARL DR TO S FRED D. HAIGHT DR ON HWY 101 ACROSS SMITH RIVER.
QA Service Level1 (Verified on 03/26/2021)

Sample Information

Sample Taken Date08/29/2023 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/11/2023
Sample typeQuality Assurance A brief description of the sampleAB549A SHT Brace Bolt
The quantity of what the sample constitutes1162 From where was the sample collectedDistributor
First name of sampler or witnessed byPaul Last name of sampler or witnessed byFarinha
Title of samplerASI Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAcrow bridge Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS51-895-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)10810540, 32310130, 5805574803 Nut Mfg. Lot Number(s)38483-5805574803
Washer Mfg. Lot Number(s)0523-742 Bolt SpecificationA325
Bolt Length(s)2-3/4" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size1" Bolt Mfg. Lot NumberE319G1
Rocap Test Requirement(s) Lubricant Requirements(s)lubricated

Test Details

DIME Sample ID: 2023-08-29-6
DIME Test ID: 2023-08-29-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-09-20

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 09/18/2023
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A98729Proof Load

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 9/20/2023