Summary for Test 2017-02-08-6-1

Test performed: ASTM C39-17a

Project Information

Project IdentifiersProject ID: 209950
DEA: 080N56U4
EFIS: 0813000176
DIST-CO-RTE-PM08-SBD-40-R94.7/R99.7
Award Date01/22/2015
Closeout Date09/17/2018
Work DescriptionBRIDGE REPLACEMENTS.
Location DescriptionSAN BERNARDINO COUNTY NEAR ESSEX AT HALLER WASH BRIDGE AT ROJO WASH BRIDGE AND AT CLIPPER VALLEY WASH BRIDGE
QA Service Level1 (Verified on 04/29/2015)

Sample Information

Sample Taken Date02/08/2017 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing02/10/2017 Sample typeQuality Control
A brief description of the sample6x12 The quantity of what the sample constitutes6
From where was the sample collectedJob Site First name of sampler or witnessed byAAE
Last name of sampler or witnessed byNP Title of samplerASR
Telephone number of samplerUnknown Laboratory sample identification907-17
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameROBERTSONS
Transportation Laboratory (TL) Number178317 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierFULL BRIDGE DECK POUR Structure nameBRIDGE DECK FROM PUMP
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberRRM16074
The truck number from where the sample was collected1728 The batch plant ticket number from where the sample was collected2256646
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedLOAD 7 Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2017-02-08-6
DIME Test ID: 2017-02-08-6-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-02-21

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 02/20/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 110800 lb
Maximum load on cylinder 2: 108950 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 12 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 3905.5 psi
Compressive strength of cylinder 2: 3828.2 psi
Compressive strength (to nearest 10 psi): 3870 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/21/2017 ✔